- Sensing Mode (General)
- Proximity
- Sensing Mode (Detailed)
- Time of Flight
- Housing Style
- Rectangular
- Primary Housing Material
- Polybutylene Terephthalate (PBT)
- Input/Output
- Analog
- Indicator Display Type
- LEDs
- Analog Output
- 0-10 VDC or 4-20 mA
- Analog Resolution/Discrete Repeatability
- 1 mm
- Max Sensing Distance
- 6000 mm
- Minimum Sensing Distance
- 200 mm
- Sensing Beam
- Ultrasonic
- Power Supply
- 13 to 30 VDC
- Delay at Power-up
- 1500 ms
- Adjustments
- Push Button(s)
- Temperature Effect
- Uncompensated: 0.2% of distance/deg C, Compensated: 0.02% of distance/deg C
- Connection
- Cable
- QD Type/Cable Length
- 2 m
- Number of Pins
- 5 Pin
- Vibration
- MIL-STD-202F req. Method 201A (vibration: 10 to 60 Hz max., double amplitude 0.06 in, max acc. 10G).
- Mechanical Shock
- IEC 60947-5-2 Requirements: 30G 11 ms Duration, Half Sine Wave
- Analog Current Output Rating
- 1 k or [(Vcc-5 V)/0.02 A], whichever is lower
- Analog Voltage Output Rating
- 500 Min. Load Impedance
- Output Protection
- Protected against short circuit conditions
- IP Rating
- IP67
- NEMA Rating
- NEMA 6P
- Storage Temperature
- -40 to 90 deg C (-40 to 194 deg F)
- Max Operating Temperature
- 50 deg C (122 deg F)
- Min Operating Temperature
- -20 deg C (-4 deg F)
- Max Op. Relative Humidity Non-Condensing (%)
- 100%
- Warm-up Time
- 15 min
- Temperature Warm-up Drift upon Power-up
- < 7% of the sensing distance upon power-up
- Temp. Warm-up Drift (Notes 1)
- After 5 min, the apparent switchpoint is < 0.6% of the actual position.
- Temp. Warm-up Drift (Notes 2)
- After 25 min, the sensing position will be stable.
- Minimum Response Time
- 100 ms
- Rep Rate
- 96 ms
- Analog Linearity
- +/- 0.2% of span from 200 to 8000 mm; +/- 0.1 % of span from 500 to 8000 mm (1 mm minimum)
- Barrel Diameter
- 56 mm
- Minimum Window Size
- 20 mm
- Ultrasonic Frequency
- 75 kHz
- Power/Current Consumption (Exclusive of Load)
- 100 mA max @ 10 VDC; 40 mA max @ 30 VDC
- Supply Protection Circuitry
- Protected against reverse polarity and transient overvoltages
- Feature: Remote Teach
- Yes
- Feature: Clear Object Detection
- Yes
- Feature: Timing (Hold/Delay)
- No
- Feature: Chemical Resistant
- Yes
- Application: Ultrasonic
- Yes
- IO Link
- No
- RS-232
- No
- RS-422
- No
- RS-485
- No
- SSI
- No
- Wireless
- No Wireless Capability
- 1-Wire Serial Interface
- No
- Profibus
- No
Customer Service